- The Critical Importance of Indoor Air Quality in Healthcare
Indoor Air Quality in Healthcare: Why It Matters and How to Improve It
In hospitals, clinics, and care facilities, the air patients and staff breathe can contain contaminants from both everyday activities and outdoor pollution.
Airborne microorganisms, cleaning chemicals, and dust can accumulate in healthcare buildings when pollution sources are poorly controlled or ventilation is inadequate. Patients with respiratory conditions or weakened immune systems may be particularly susceptible to these exposures.
These risks raise critical, practical questions for healthcare facilities, such as:
- Which contaminants need attention?
- What ventilation guidance applies?
- How can additional air treatment improve the air quality?
This article examines the causes of poor indoor air quality in healthcare settings and the measures facilities can take to reduce exposure.
Why Indoor Air Quality Matters in Healthcare
Indoor air quality in healthcare matters because some occupants are more vulnerable to airborne contaminants, while others face prolonged exposure during treatment or work. Risks vary by group:
- Patients with respiratory conditions: Airborne particles and chemical irritants may trigger or worsen symptoms
- Immunocompromised patients: Certain airborne microorganisms pose a greater infection risk
- Healthcare staff: Repeated exposure to contaminants from cleaning, waste handling, and maintenance may cause irritation or discomfort
- Visitors: Respiratory particles released by an infectious person can also expose others sharing an indoor space
Ventilation helps dilute and remove these particles, while particular clinical areas may require controlled airflow to limit their movement between rooms.
What Causes Poor Indoor Air Quality in Healthcare Facilities?
Contaminants can be generated inside a building or enter through outdoor air supplies.
Airborne Microorganisms
Breathing, speaking, and coughing release respiratory particles, some of which may carry infectious microorganisms. In occupied rooms, inadequate ventilation can allow these particles to accumulate.
The risk varies with the infection involved and the activities taking place. Facilities teams should assess ventilation alongside infection-prevention procedures, particularly in areas treating patients who need additional protection.
VOCs and Chemical Pollutants
Volatile organic compounds, or VOCs, can be emitted by paints, adhesives, furnishings, and some cleaning products. Disinfecting equipment or using certain laboratory chemicals can release potentially dangerous vapours if not controlled properly.
The health risk depends on several factors, including:
- Which chemical is present and its concentration in the air
- How long someone breathes it in
- How often they are exposed
A strong smell does not necessarily mean a greater risk, and some pollutants have no noticeable odour.
Dust, Outdoor Pollution and Moisture
Indoor building work can release dust into occupied areas if the area is not adequately contained. Dust can also accumulate on surfaces and become airborne when disturbed.
Outdoor particles from traffic or nearby activities can enter through windows or ventilation intakes. If outdoor air is being brought into a facility, appropriate filtration may be needed where the incoming air is polluted.
Leaks, condensation and unresolved damp can support mould growth. Addressing the moisture source is necessary to prevent recurrence.
Odours and Ventilation Faults
Waste storage, sanitary facilities, and drainage problems can produce persistent odours. Removing or repairing the source is generally more effective than attempting to mask the smell.
Blocked filters, obstructed grilles, and equipment faults can reduce ventilation performance. A system may continue running even though it is not delivering the airflow the space requires.
UK Guidance for Healthcare Air Quality and Ventilation
NHS England’s Health Technical Memorandum 03-01 provides guidance on specialised ventilation for healthcare premises.
The guidance is divided into two parts:
- Part A: Designing and installing ventilation systems, including testing before they enter service
- Part B: Managing existing systems through ongoing maintenance and routine testing
Specific ventilation requirements depend on clinical use. Facilities should establish which guidance applies to each area rather than adopting one air-change target across the building.
General workplace requirements also apply. The Health and Safety Executive’s ventilation guidance explains the duty to provide sufficient fresh or purified air in enclosed workplaces. This general guidance should be considered alongside specialist healthcare requirements.
General workplace requirements also apply. The Health and Safety Executive’s ventilation guidance explains the duty to provide sufficient fresh or purified air in enclosed workplaces. This general guidance should be considered alongside specialist healthcare requirements.
How to Improve Indoor Air Quality in Healthcare Facilities
Improving indoor air quality involves the following steps:
Control Contaminants at Their Source
Source control reduces the quantity of pollutants that ventilation and air treatment systems must manage. Depending on the assessment, actions may include:
- Reviewing: Check how cleaning products are diluted, applied and stored
- Containing: Isolate refurbishment work to prevent dust reaching occupied areas
- Improving: Adjust waste storage and collection to address odours
- Repairing: Fix leaks and investigate recurring condensation
- Assessing: Determine whether particular activities require dedicated extraction
Any changes must continue to meet established guidelines and requirements. A substitute cleaning product, for example, must still meet the facility’s disinfection requirements. Where a hazardous substance is involved, general room ventilation may be insufficient, and the activity may require more targeted exposure controls.
Check Ventilation Performance
Confirm how the ventilation system supplies outdoor air, extracts indoor air, and serves individual rooms. In specialised clinical areas, checks may also need to establish whether airflow direction and pressure relationships meet the intended requirements.
Inspect accessible grilles for obstruction or any faults affecting airflow. Filter replacement and other maintenance should follow the applicable procedures, with records showing what was checked and any corrective work completed.
Review ventilation when a room’s use changes. Converting an office into a treatment space or increasing occupancy can create requirements that the original system was not designed to meet.
Match Air Treatment to the Contaminant
Air treatment equipment should be selected according to the contaminant being controlled and the conditions in the room.
For example, a device designed to remove dust or infectious aerosols may leave gaseous pollutants and odours untreated. Selection should therefore match the technology to the contaminant: HEPA filtration for particles, suitable adsorbent media for specific gases, or UVC to inactivate airborne microorganisms.
NHS England’s HEPA guidance and UVC guidance help facilities assess performance and safe use.
Before selecting equipment, assess:
- Documented performance under conditions relevant to the proposed use
- Capacity in relation to room volume and the required cleaning effect
- Positioning and potential obstructions to airflow
- Noise at the operating setting needed
- Maintenance requirements and ongoing operating costs
Additionally, establish how the device will work alongside existing ventilation.
Investigate Problems and Reassess Changes
Persistent odours, damp, or ventilation faults may indicate problems with pollution sources or existing systems that additional air filtration alone would not resolve.
Check whether ventilation supplies and extracts enough air for the room’s use. If a particular chemical or dust is a concern, measure its concentration in the air as well. Adequate airflow alone does not confirm that pollutants are sufficiently controlled.
Repeat these assessments when services relocate, occupancy changes, or building work affects ventilation.
Planning Air Quality Improvements
An air-quality improvement plan should link each affected space to the contaminants requiring control and specify how they will be addressed. Prioritise actions according to clinical risk, with clear responsibility for completing the work and checking its effectiveness.
This gives facilities teams a basis for deciding whether source control, ventilation repairs, or additional air treatment will address the problems. It also provides a baseline for checking whether those measures continue to perform as healthcare services change.
Improving Healthcare Air Quality With Nippon Sanso’s MARCC
Nippon Sanso’s MARCC range includes three air treatment products for different indoor air quality concerns. The range can be considered for non-critical healthcare areas such as waiting rooms. Each product addresses a different need:
- MARCC BioControl: Helps reduce microbiological contamination from airborne bacteria, viruses and fungi.
- MARCC BioVOC: Combines microbiological control with photocatalytic treatment of selected volatile organic compounds (VOCs) and odours.
- MARCC VOCControl: Uses photocatalytic treatment to address selected gaseous pollutants, including VOCs and nitrogen oxides, as well as persistent odours.
MARCC products are designed to integrate into compatible heating, ventilation and air conditioning (HVAC) systems, including air handling units and ventilation ducts. They provide supplementary air treatment and do not replace ventilation, air exchange, HVAC filtration or routine cleaning. MARCC is not a medical device.
Contact Nippon Sanso to discuss which MARCC product addresses your facility’s air quality concerns and whether it can be integrated into your existing system